≈ 7.5 nights (8h/night)
System standby power: 25W (36.7% of total draw)
≈ 7.5 nights (8h/night) · Safe motor start buffer (99.2% margin).
CPAP machine running (65 W max) and start-up (90 W max) draw fit the EcoFlow DELTA Pro 3's 4,000 W continuous / 8,000 W surge ratings.
humidifier and heated tube off (15 W)
standard pressure with humidifier active (40 W)
high pressure with HumidAir and heated tube at max (65 W)
Via ResMed Air11 90 W DC/DC Converter (part 39231)
Via ResMed Air11 90 W DC/DC Converter (part 39231)
Via ResMed Air11 90 W DC/DC Converter (part 39231)
≈ 7.5 nights (8h/night)
System standby power: 25W (36.7% of total draw)
Provides 4× CEE 7/3 (230V), 1× IEC Commando (32A), 1× Commando (16A/32A) (120/240V 60Hz).
Pure sine wave inverter output. Safe for sensitive medical electronics and variable-speed motors.
Inductive motor/compressor load with 1.6× starting surge (motor inrush) (99.2% worst-case surge margin).
Wall AC fast charge at up to 3000W (70m to 80%, 95m to 100%).
Safe envelope verified: Starting surge (65W) remains comfortably below the 8000W surge trip line, with steady-state operation settling into the safe continuous zone at 40W.
About 60 hours on AC power, with the CPAP machine averaging 40 W (standard pressure with humidifier active (40 W)). The EcoFlow DELTA Pro 3 then draws about 68 W from its battery, including 25 W for the inverter itself. Best case: about 4.1 days (humidifier and heated tube off (15 W)). Worst case: about 43 hours (high pressure with HumidAir and heated tube at max (65 W)). At 8 hours a night, that's about 7.5 nights.
Yes. Using the ResMed Air11 90 W DC/DC Converter (part 39231) on the EcoFlow DELTA Pro 3's 12 V car socket, the CPAP machine runs about 4.4 days instead of 60 hours on AC, 74% longer, because it skips the inverter's conversion loss and its 25 W idle draw. That's 13 nights instead of 7.5 nights.
That simple division gives 4.3 days, but the EcoFlow DELTA Pro 3's inverter draws about 25 W whenever its AC outlets are on. At this light load that's 37% of everything the battery supplies, and inverter conversion losses take a further share. The idle figure comes from EcoFlow.
On wall power: about 70 minutes to 80% and 95 minutes to full (EcoFlow figures). With its maximum 2,600 W of solar input connected, expect about 2,080 W in full sun, so a full recharge takes roughly 2.1 hours of full sun, so it can refill in a single day with 4 peak sun hours.
It can act as a backup supply: with the CPAP machine plugged into the EcoFlow DELTA Pro 3 and the EcoFlow DELTA Pro 3 plugged into the wall, it switches the CPAP machine to battery in about 10 ms when the grid fails (EcoFlow calls this UPS mode).
Statutory 30-day retail price announcements & rate revisions
Bord Gáis Energy winter rate adjustment: +1.60c/kWh Day, +0.90c/kWh Boost (2am–5am), and +€12.50/yr standing charge effective 20 Nov 2026.
Energia retail revision: +1.85c/kWh Day, +1.15c/kWh EV Boost (2am–6am), and +€14.20/yr standing charge effective 15 Nov 2026.
Dual Fuel Day Night: Day -4.64c/kWh, Night -3.25c/kWh (effective 2026-11-05)
Electricity Day Night: Day -4.64c/kWh, Night -3.25c/kWh (effective 2026-11-05)
SSE Airtricity statutory price cut: -1.25c/kWh Day, -0.65c/kWh Night, and -€8.40/yr standing charge effective 01 Oct 2026.
Powered by daily verified feeds from Alva Compare & CRU disclosures.