≈ 4.4 nights (8h/night)
System standby power: 15W (25.8% of total draw)
≈ 4.4 nights (8h/night) · Safe motor start buffer (98.6% margin).
CPAP machine running (65 W max) and start-up (90 W max) draw fit the EcoFlow DELTA 2 Max's 2,400 W continuous / 4,800 W surge ratings.
humidifier and heated tube off (15 W)
standard pressure with humidifier active (40 W)
high pressure with HumidAir and heated tube at max (65 W)
Via ResMed Air11 90 W DC/DC Converter (part 39231)
Via ResMed Air11 90 W DC/DC Converter (part 39231)
Via ResMed Air11 90 W DC/DC Converter (part 39231)
≈ 4.4 nights (8h/night)
System standby power: 15W (25.8% of total draw)
Provides 6× CEE 7/3 (230V) (120V 60Hz).
Pure sine wave inverter output. Safe for sensitive medical electronics and variable-speed motors.
Inductive motor/compressor load with 1.6× starting surge (motor inrush) (98.6% worst-case surge margin).
Wall AC fast charge at up to 1800W (66m to 80%, 80m to 100%).
Safe envelope verified: Starting surge (65W) remains comfortably below the 4800W surge trip line, with steady-state operation settling into the safe continuous zone at 40W.
About 35 hours on AC power, with the CPAP machine averaging 40 W (standard pressure with humidifier active (40 W)). The EcoFlow DELTA 2 Max then draws about 58 W from its battery, including 15 W for the inverter itself. Best case: about 66 hours (humidifier and heated tube off (15 W)). Worst case: about 24 hours (high pressure with HumidAir and heated tube at max (65 W)). At 8 hours a night, that's about 4.4 nights.
Yes. Using the ResMed Air11 90 W DC/DC Converter (part 39231) on the EcoFlow DELTA 2 Max's 12 V car socket, the CPAP machine runs about 52 hours instead of 35 hours on AC, 49% longer, because it skips the inverter's conversion loss and its 15 W idle draw. That's 6.6 nights instead of 4.4 nights.
That simple division gives 51 hours, but the EcoFlow DELTA 2 Max's inverter draws about 15 W whenever its AC outlets are on. At this light load that's 26% of everything the battery supplies, and inverter conversion losses take a further share. EcoFlow doesn't publish an idle figure and we haven't found an independent measurement, so this uses our 15 W estimate.
On wall power: about 66 minutes to 80% and 80 minutes to full (EcoFlow figures). With its maximum 1,000 W of solar input connected, expect about 800 W in full sun, so a full recharge takes roughly 2.7 hours of full sun, so it can refill in a single day with 4 peak sun hours.
It can act as a backup supply: with the CPAP machine plugged into the EcoFlow DELTA 2 Max and the EcoFlow DELTA 2 Max plugged into the wall, it switches the CPAP machine to battery in about 20 ms when the grid fails (EcoFlow calls this UPS mode).
Statutory 30-day retail price announcements & rate revisions
Bord Gáis Energy winter rate adjustment: +1.60c/kWh Day, +0.90c/kWh Boost (2am–5am), and +€12.50/yr standing charge effective 20 Nov 2026.
Energia retail revision: +1.85c/kWh Day, +1.15c/kWh EV Boost (2am–6am), and +€14.20/yr standing charge effective 15 Nov 2026.
Dual Fuel Day Night: Day -4.64c/kWh, Night -3.25c/kWh (effective 2026-11-05)
Electricity Day Night: Day -4.64c/kWh, Night -3.25c/kWh (effective 2026-11-05)
SSE Airtricity statutory price cut: -1.25c/kWh Day, -0.65c/kWh Night, and -€8.40/yr standing charge effective 01 Oct 2026.
Powered by daily verified feeds from Alva Compare & CRU disclosures.