≈ 0.4 days (12h/day)
System standby power: 10W (5.7% of total draw)
≈ 0.4 days (12h/day) · Safe motor start buffer (68.8% margin).
pellet stove running (220 W max) and start-up (750 W max) draw fit the EcoFlow RIVER 2 Pro's 800 W continuous / 1,600 W surge ratings.
Modulated low fire: motorized auger feed and exhaust fan running continuously (100 W)
Medium fire heat setting: continuous combustion blower, room fan, and intermittent auger (150 W)
Startup ignition cycle: ceramic electric glow igniter element active for first 15 minutes (500 W peak)
≈ 0.4 days (12h/day)
System standby power: 10W (5.7% of total draw)
Provides 4× BS 1363 (230V) (120V 60Hz).
Pure sine wave inverter output. Safe for sensitive medical electronics and variable-speed motors.
Inductive motor/compressor load with 3.3× starting surge (motor inrush) (68.8% worst-case surge margin).
Wall AC fast charge at up to 940W (55m to 80%, 70m to 100%).
Safe envelope verified: Starting surge (500W) remains comfortably below the 1600W surge trip line, with steady-state operation settling into the safe continuous zone at 150W.
About 4.4 hours on AC power, with the pellet stove averaging 150 W (Medium fire heat setting: continuous combustion blower, room fan, and intermittent auger (150 W)). The EcoFlow RIVER 2 Pro then draws about 175 W from its battery, including 10 W for the inverter itself. Best case: about 6.4 hours (Modulated low fire: motorized auger feed and exhaust fan running continuously (100 W)). Worst case: about 3 hours (Startup ignition cycle: ceramic electric glow igniter element active for first 15 minutes (500 W peak)). At 12 hours a day, that's about 0.4 days.
Yes. The pellet stove's start-up peak of about 500 W (up to 750 W) fits within the EcoFlow RIVER 2 Pro's 1,600 W surge rating, with 53% headroom even in the worst case.
On wall power: about 55 minutes to 80% and 70 minutes to full (EcoFlow figures). With its maximum 220 W of solar input connected, expect about 176 W in full sun, so a full recharge takes roughly 4.6 hours of full sun, about 1.2 days at 4 peak sun hours a day.
It can act as a backup supply: with the pellet stove plugged into the EcoFlow RIVER 2 Pro and the EcoFlow RIVER 2 Pro plugged into the wall, it switches the pellet stove to battery in about 30 ms when the grid fails (EcoFlow calls this EPS mode).
Statutory 30-day retail price announcements & rate revisions
Bord Gáis Energy winter rate adjustment: +1.60c/kWh Day, +0.90c/kWh Boost (2am–5am), and +€12.50/yr standing charge effective 20 Nov 2026.
Energia retail revision: +1.85c/kWh Day, +1.15c/kWh EV Boost (2am–6am), and +€14.20/yr standing charge effective 15 Nov 2026.
Dual Fuel Day Night: Day -4.64c/kWh, Night -3.25c/kWh (effective 2026-11-05)
Electricity Day Night: Day -4.64c/kWh, Night -3.25c/kWh (effective 2026-11-05)
SSE Airtricity statutory price cut: -1.25c/kWh Day, -0.65c/kWh Night, and -€8.40/yr standing charge effective 01 Oct 2026.
Powered by daily verified feeds from Alva Compare & CRU disclosures.