WILL POWER YOUR SPACE HEATER230V AC
59MIN
Continuous: 900W
Surge Peak: 900W

≈ 0.0 days (24h/day) · Safe motor start buffer (66.7% margin).

Ready to Run
Motor Start Margin+1800W Safe Buffer(900W Peak / 2700W Max)

How long will an EcoFlow DELTA 2 run a space heater?

space heater running (1,500 W max) and start-up (1,500 W max) draw fit the EcoFlow DELTA 2's 1,800 W continuous / 2,700 W surge ratings.

LOW LOAD
1.2HRS

low heat setting (750 W continuous)

750 W857.22 W net
TYPICAL SPECNOMINAL
59MIN

medium heat setting or thermostat-cycled high heat (900 W)

900 W1034.25 W net
HIGH LOAD
35MIN

high heat setting continuous (1,500 W, 12.5 A at 120 V)

1500 W1773.5 W net
TELEMETRY // PRIMARY READOUT230V AC
CALIBRATED RUNTIME
59MIN

≈ 0.0 days (24h/day)

NET PACK DRAW
1034.25W

System standby power: 15W (1.5% of total draw)

CONTINUOUS_LOAD_UTILIZATION50% (900W / 1800W)
APPLIANCE_DRAW900W RUN / 900W PK
SOURCE_LIMIT1800W CONT / 2700W PK
SOLAR_RECHARGE (500W)2.69H (0.67D)
PARAMETER_SANDBOX // ENGINE v1.0.0

Live Load, Duty Cycle & Usage Simulator

900 W
MIN 375WNOMINAL 900WMAX 2100W
100%
5% INTERMITTENT50% CYCLING100% CONTINUOUS
24 h/day
1H / DAY8H OVERNIGHT24H CONTINUOUS
0 W
0W (OFF)200WMAX 500W
TEMPERATURE DERATE
CONTINUOUS
59MIN
OUTAGE SPAN
0.0days
AVG LOAD
900W
PACK DRAW
1034.25W
Stack space heater with other devices on EcoFlow DELTA 2 in the Load BuilderOpen Builder →
HARDWARE_INTERFACE // ELECTRICAL AUDIT

EcoFlow DELTA 2 × 1,500W Portable Space Heater Electrical Interface

1. AC RECEPTACLE & PLUG MATCH
BS 1363 / Europlug (230V 13A Domestic) → DIRECT FIT

Provides 2× CEE 7/3 (230V) (120V 60Hz).

2. WAVEFORM & THD SENSITIVITY
PURE SINE WAVE // STANDARD LOAD

Pure sine wave inverter output. Safe for all standard household appliances.

3. STARTING SURGE (MOTOR INRUSH) MARGIN
900W TYP (1500W MAX) VS 2700W LIMIT

Electronic/resistive load with 1× start-up profile (66.7% surge margin).

4. UPS SWITCHOVER & EXPANSION
UPS: EPS (30MS) · EXPAND: UP TO 3072WH

Wall AC fast charge at up to 1200W (50m to 80%, 80m to 100%).

PHYSICS // TRANSIENT DRAW ENVELOPE

Dynamic Inrush Surge Curve (Locked Rotor Amps vs Steady State)

SAFE INRUSH HEADROOM (+1800W BUFFER)
0ms250ms500ms750ms1000ms0W2s Surge Limit (2700W)2700WContinuous Rating (1800W)1800WStartup: 900WRunning (FLA): 900W

Safe envelope verified: Starting surge (900W) remains comfortably below the 2700W surge trip line, with steady-state operation settling into the safe continuous zone at 900W.

LAB_RECORDS // EMPIRICAL OBSERVATIONS

Field Engineering Quirks & Operational Failure Modes

Hardware Bench Constraints (EcoFlow DELTA 2)
  • ›X-Boost engages automatically above 1,800 W and runs resistive loads up to 2,200 W at reduced voltage. EcoFlow says it's meant for heating loads, not voltage-sensitive devices, and it's unavailable while the AC output is in wall-charging bypass.
  • ›EPS mode: on wall power, connected loads run from the grid and switch to battery within 30 ms if the power fails. EcoFlow says this is not 0 ms and not suitable for servers or workstations.
  • ›The AC output switches off after 12 hours with no load; set the app's AC timeout to 'Never' for intermittent loads such as fridges.
  • ›Only 2 of the 6 AC outlets are grounded (NEMA 5-20R); the other 4 are two-prong NEMA 1-15R.
  • ›The car socket and both DC5521 ports share one 126 W budget.
  • ›EcoFlow's US product page lists 3,000 cycles to 80%, while the July 2025 US manual says 4,000; we use 3,000.
Cycle Physics & Dwell Behavior (1,500W Portable Space Heater)
  • ›UL 1278 caps standard 15 A / 120 V cord-connected portable heaters at 1,500 W continuous (80% of an 1,800 W branch circuit), draining a 1,000 Wh power station in about 35–40 minutes on High.
  • ›Purely resistive heaters have no motor start-up spike (surge watts equal running watts) and are the primary load class supported by voltage-reduction modes such as EcoFlow X-Boost, Anker SurgePad, and Bluetti Power Lifting.
  • ›Always plug a 1,500 W heater directly into the power station or generator receptacle rather than through a light-gauge extension cord to prevent plug overheating at 12.5 A continuous draw.
KNOWLEDGE_BASE // VERIFIED QA

Frequently Asked Questions: EcoFlow DELTA 2 & 1,500W Portable Space Heater

How long will an EcoFlow DELTA 2 run a space heater?

About 59 minutes on AC power, with the space heater averaging 900 W (medium heat setting or thermostat-cycled high heat (900 W)). The EcoFlow DELTA 2 then draws about 1,034 W from its battery, including 15 W for the inverter itself. Best case: about 1.2 hours (low heat setting (750 W continuous)). Worst case: about 35 minutes (high heat setting continuous (1,500 W, 12.5 A at 120 V)).

How long does the EcoFlow DELTA 2 take to recharge?

On wall power: about 50 minutes to 80% and 80 minutes to full (EcoFlow figures). With its maximum 500 W of solar input connected, expect about 400 W in full sun, so a full recharge takes roughly 2.7 hours of full sun, so it can refill in a single day with 4 peak sun hours.